4 Room Semi-Automatic Ripening Systems
Model: Fruitron 1.04SA
Centralized ripening controller that supports 4 ripening rooms.
Cost effective automated solution from Chemtron best suited for small scale ripeners targeting average to good quality of ripened fruits.
This solution is best suited for ripening chambers of 6 to 12 tons of fruit capacity.
The controller controls ethylene dosing and CO2 venting based on preset time intervals by the user.
Ethylene Control:
- User can set dose time between 10 – 99 hours in 4 intervals as required by the commodity and market conditions
- The controller controls Ethylene gas in the room by dispensing it in short bursts at fixed intervals of time
- User can set frequency of dosing between 1 to 99 cycles of desired time period between 5 to 20 seconds
- The controller ensures 100 to 150 PPM of Ethylene during the dosing time irrespective of the losses of Ethylene due to leakages in the cold room
- Works best with our Gas Dispensing Unit (GDU)
CO2 Control:
- User can program CO2 vent time between 24 to 125 hours and venting frequency as per required stage of ripening for the targeted market
- The controller controls venting of CO2 in the room by controlling dampers / blowers at regular intervals of time that is user settable up to 30 minutes for every 5 hours
- The controller ensures air exchange happens in the ripening room in order to keep CO2 generation in check
- Works best with our CO2 Dampers
Specifications:
- Enclosure: SS316
- Mount: Wall
- Input: 230 VAC, 50 Hz.
- Control output: 230 VAC
- Number of control output: 2 per room
Fruitron 1.04 SA | Dose Process | Vent Process |
---|---|---|
Settings | Time: 10 to 99 hours Intervals: 4 Frequency: 1 to 99 cycles On Time: 5 to 20 seconds Off Time: 20 - 45 seconds |
Time: 24 to 125 hours On time: 5 to 30 minutes Off Time: 15 – 300 minutes |
Control Output | 230 VAC | 230 VAC |
Control Device / Accessory | Gas Dispensing Unit (GDU) | CO2 Dampers |
8 Room Semi-Automatic Ripening Systems
Model: Fruitron CRC8 3.0SA
Centralized ripening controller that supports 8 ripening rooms.
Cost effective automated solution from Chemtron best suited for small scale ripeners targeting average to good quality of ripened fruits.
This solution is best suited for ripening chambers of 6 to 12 tons of fruit capacity.
The controller controls ethylene dosing and CO2 venting based on preset time intervals by the user.
Ethylene Control:
- User can set dose time between 10 – 99 hours in 4 intervals as required by the commodity and market conditions
- The controller controls Ethylene gas in the room by dispensing it in short bursts at fixed intervals of time
- User can set frequency of dosing between 1 to 99 cycles of desired time period between 5 to 20 seconds
- The controller ensures 100 to 150 PPM of Ethylene during the dosing time irrespective of the losses of Ethylene due to leakages in the cold room
- Works best with our Gas Dispensing Unit (GDU)
CO2 Control:
- User can program CO2 vent time between 24 to 125 hours and venting frequency as per required stage of ripening for the targeted market
- The controller controls venting of CO2 in the room by controlling dampers / blowers at regular intervals of time that is user settable up to 30 minutes for every 5 hours
- The controller ensures air exchange happens in the ripening room in order to keep CO2 generation in check
- Works best with our CO2 Dampers
Specifications:
- Enclosure: SS316
- Mount: Wall
- Input: 230 VAC, 50 Hz.
- Control output: 230 VAC
- Number of control output: 2 per room
Fruitron CRC8 3.0SA | Dose Process | Vent Process |
---|---|---|
Settings | Time: 10 to 99 hours Intervals: 4 Frequency: 1 to 99 cycles On Time: 5 to 20 seconds Off Time: 20 - 45 seconds |
Time: 24 to 125 hours On time: 5 to 30 minutes Off Time: 15 – 300 minutes |
Control Output | 230 VAC | 230 VAC |
Control Device / Accessory | Gas Dispensing Unit (GDU) | CO2 Dampers |